Language EnglishVertical Tabs General Designed to supply steam at peak loads of a plant Specially it suitable for the plants having periodical peak loads like EPS or glass raw material drying plants to reduce steam boiler capacity to mean load Capacity Range Manufactured according to customer request at the capacity ranging from 1 m3 to 1 m3 in volume and at the different charg and discharge pressure Standard Operation Accessories Accumulator tank Steam charging diffuser Inlet, outlet and by-pass valves Checkvalve, strainers Modulating pressure control valve or pressure reducer Make up water inlet valve Drainage valve Airwent valve Water level gauge Overfloat steam trap Pressure gauge Safety valve Operation features Installed in new or existing steam plants It accumulates steam when the load of plant drops It offers steam when the peak load occurs in plant It offers to select steam boiler capacity according to mean load of plant instead of peak load It works automatically according to thermodynamic principles Manufacturing features Manufactured with high quality certified boiler sheet in accordance with EN 13445 All weldings are made by welders certified in accordance with EN 9606-1 All weldings are controlled by NDT technicians and UT test is applied to a certain percentage of them Whole body is painted double coat with heat resistant paint Insulated with rock wool and covered color galvanized sheet Handhole and manhole (if the shell diameter more than 1400 mm) on it offers easy cleaning of water side Mounted on power pedestal ARALSAN's warranty extendable up to 5 years